Skip to content
Pariksha Studio™
3 marksCBSE board 2024Electric power

Asked in: CBSE Board 2024 (Main)

Explain in brief the function of an electric fuse in a domestic circuit. An electric heater of current rating 3 kW; 220 V is to be operated in an electric circuit of rating 5 A. What is likely to happen when the heater is switched 'ON' ? Justify your answer with necessary calculation.

How the 3 marks are given

  • Function of the fuse1 mark
  • Calculation of current 13.6 A1 mark
  • Conclusion that fuse melts1 mark

Step-by-step solution

  1. Step 1: Fuse: a wire of low melting point connected in series; when the current exceeds the safe value, it melts and breaks the circuit.
  2. Step 2: I = P/V = 3000/220 = 13.6 A
  3. Step 3: Circuit rating is only 5 A, so the fuse blows and the heater will not work.